UL CLASSIFICATIONS
MAINTENANCE AND REPAIR SYSTEMS
Unless otherwise indicated, the base sheet may be mechanically
secured, spot or fully adhered along with the ply, cap sheet and/or polyester
with hot asphalt, "Fields F100 PowrCoat" or "Fields F110
PowrLap" at the rate of 2.5 or more gal/sq or hot roofing asphalt.
"Fields MT3 RubrPac" or "Fields MT4 RubrPac" may be
substituted for hot asphalt in all applicable Classifications, which do
not exceed 1/2 in. incline for cap sheet systems.
"Fields M100 RubrCoat" may be substituted for "Fields F100
PowrCoat" in all applicable Classifications, which do not exceed
1/2 in. incline.
"Fields M150 RubrSeal" may be substituted for "Fields F110
PowrLap" in all applicable Classifications, which do not exceed 1/2
in. incline.
"Fields F600 FlameBloc", may be substituted for Fields 600 series
Aluminum Coating in all Classifications.
Type G3 "F58 GlasCap" may be substituted as a surfacing option
in all applicable Classifications.
"Fields T3 Type 3", "Fields T4 Type 4 (hot asphalt)",
"Fields MT3 RubrPac" or "Fields MR4 RubrPac" (SEBS
modified hot asphalt) may be substituted for "Fields F100 PowrCoat",
"Fields M100 RubrCoat", "Fields F100 PowrLap" or "Fields
M150 RubrSeal" in all applicable Classifications, which do not exceed
1/2 in. incline.
"Fields M62 RubrGlas" or "Fields M66 RubrGlas2" may
be substituted for "Fields Glass" Type G1 and G2 products in
all Classifications.
"Fields M700 RubrGard" may be substituted for "Fields F700
PowrGard" in all applicable Classifications.
EPS/composite or EPS/perlite as a roofing insulation may be used when
hot roofing asphalt is used to adhere the base, ply, cap sheet or polyester.
Refer to "MAINTENANCE AND REPAIR SYSTEMS" at the beginning of
this product category for clarification of other systems in this category.
Two Type G1 products may be substituted for one Type G2 product in any
of the following Classifications.
Class A
1. Deck: NC Incline: 1/2
Existing Roof System: Class A or B covered with:
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite,
or PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G2 product.
Ply Sheet (Optional): One or more layers "Fields Glass"
Type G1 or G2 product or "Fields M66 RubrGlas2".
Polyester: One or more layers polyester (Max weight 3 oz/sq yd)
(Not UL Classified), applied in "Fields F100 PowrCoat", "Fields
F110 PowrLap", "Fields M700 RubrGard", "Fields F700
PowrGard " or "Fields F750 PowrGard2", 2.5-3.5 gal/sq.
Coating and Surfacing Options:
Note: The following systems A through C are options only when "Fields
F100 PowrCoat" or "Fields F110 PowrLap" is used to adhere
the base, ply and/or Polyester.
A. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap ", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield"
or "Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
1-2 gal/sq.
B. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap ", 2.5 or more gal/sq.
Surfacing: "Fields M800 RubrStar" or "Fields F880
SunGard", 1-2 gal/sq.
C. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: "Fields M860 PolrBrite" or "Fields M850
PolrShield", 1-2 gal/sq.
Note: The following systems D through F are options only when "Fields
M700 RubrGard", "Fields F700 PowrGard" or "Fields
F750 PowrGard2" are used to adhere the Polyester.
D. Coating: "Fields M700 RubrGard", 2.5 or more gal/sq.
Surfacing (Optional): "Fields F540 SunShield 2 or F550 SunShield",
"Fields F640 SolrSheild2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard", "Fields
M860 PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq
or No. 11 roofing granules at 50 or more lbs/sq or aluminum flakes at
3 or more lbs/sq.
E. Coating: "Fields F700 PowrGard", "Fields F750
PowrGard2", "Fields M800 RubrStar" or "Fields F880
SunGard", 2.5 or more gal/sq.
F. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 3 or more gal/sq with or without chopped roving glass,
1 lb. or more/sq.
Surfacing (Optional): "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard", "Fields
M860 PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq.
2. Deck: NC Incline: 1/2
Existing Roof System: Class A or B covered with:
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite
or PAROC roof insulation.
Base Sheet (Optional): One or more layers polyester (max weight 5.4
oz/sq yd)(Not UL Classified)
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product or "Fields M66 RubrGlas2".
Coating and Surfacing Options:
A. Flood-Coat (Optional): Hot roofing asphalt covered with one
of the following surfaces:
Surfacing: "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
1-2 gal/sq, "Fields M800 RubrStar", "Fields F880 SunGard",
"Fields M860 PolrBrite" or "Fields M850 PolrShield",
1 or more gal/sq.
B. Coating: "Fields F100 PowrCoat", "Fields M100
RubrCoating", "Fields F110 PowrLap" or "Fields M150
RubrSeal", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
1-2 gal/sq, "Fields M800 RubrStar", "Fields F880 SunGard",
"Fields M850 PolrShield" or "Fields M860 PolrBrite",
1-2 gal.
C. Coating: "Fields F100 PowrCoat", "Fields M100
RubrCoat", "Fields F110 PowrLap" or "Fields M150 RubrSeal",
2.5 or more gal/sq.
Surfacing: Aluminum flakes at 3 or more lbs/sq or No. 11 granules
at 50 lbs/sq.
D. Coating: "Fields F700 PowrGard", "Fields M700
RubrGard" or "Fields F750 PowrGard2", 2.5 or more gal/sq.
Surfacing: Aluminum flakes at 3 lb/sq.
3. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A, B or C, gravel or smooth surfaced,
covered with:
Insulation: Any thickness, one or more layers Johns Manville "Retro-Fit"
cover board, "Fesco", "ISO 1", "ENRGY-2",
3/4 in. "Fesco" over polystyrene or any UL Classified polyisocyanurate
insulation, mechanically fastened or hot mopped.
Ply Sheet: One or more plies Type G1 or G2, hot mopped.
Membrane: "Fields M68" (modified bitumen), hot mopped.
4. Deck: NC Incline: 1/2
Existing Roof System: Class A, B or C, gravel or smooth surfaced,
covered with:
Insulation (Optional): Any thickness, one or more layers Johns
Manville "Retro-Fit" cover board, "Fesco", "ISO
1", "ENRGY-2", 3/4 in. "Fesco" over polystyrene
or any UL Classified polyisocyanurate insulation, mechanically fastened
or hot mopped.
Base Sheet: One or more plies Type G1 or G2, hot mopped.
Membrane: "Fields M68" (modified bitumen), hot mopped.
5. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A, B or C, gravel or smooth surfaced,
covered with:
Insulation: One or more layers, any thickness, Johns Manville "Fesco",
"Fesco-Foam", "ISO 1", "ENRGY-2" or any
UL Classified polyisocyanurate insulation, in combination (optional) with
1/2 in. "Retro-Fit" cover board, first layer mechanically attached,
subsequent layers adhered with "Fields F100 PowrCoat" or 3/4
in. "Fesco" over polystyrene, mechanically attached.
Base Sheet: One or more plies Type G2, mechanically fastened.
Membrane: "Fields M68" (modified bitumen), hot mopped.
6. Deck: NC Incline: 1/2
Existing Roof System: Class A, B or C, gravel or smooth surfaced,
covered with:
Insulation (Optional): One or more layers, any thickness, Johns
Manville "Fesco", "Fesco-Foam", "ISO 1",
"ENRGY-2" or any UL Classified polyisocyanurate insulation,
in combination (optional) with 1/2 in. "Retro-Fit" cover board,
first layer mechanically attached, subsequent layers adhered with "Fields
F100 PowrCoat" or 3/4 in. "Fesco" over polystyrene, mechanically
attached.
Base Sheet: One or more plies Type G2, mechanically fastened.
Membrane: "Fields M68" (modified bitumen), hot mopped.
7. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A, B or C, gravel or smooth surfaced,
covered with:
Insulation (Optional): One or more layers, any thickness, Johns
Manville "Fesco", "Fesco-Foam", "ISO 1",
"ENRGY-2" or any UL Classified polyisocyanurate insulation,
in combination (optional) with 1/2 in. "Retro-Fit" cover board,
first layer mechanically attached, subsequent layers adhered with "MBR
Cold Application Adhesive" or 3/4 in. "Fesco" over polystyrene,
mechanically attached.
Base Sheet: One or more plies Type G2, mechanically fastened.
Membrane: "Fields M68" (modified bitumen), hot mopped.
8. Deck: NC Incline: 1/2
Existing Roof System: Class A or B granule or smooth surfaced,
covered with:
Base Coat: "Fields M850 PolrShield " or "Fields
M860 PolrBrite" 2-3 gal/sq.
Polyester (Optional): One or more layers polyester (max weight 5.4 oz/sq
yd).
Surfacing: "Fields M850 PolrShield" or "Fields M860
PolrBrite", 2-3 gal/sq.
Class B
1. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A or B covered with:
Insulation: (Optional) Any thickness, one or more layers UL Classified
perlite, glass fiber, polyisocyanurate, polyisocyanurate/composite, or
PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G2 product.
Ply Sheet (Optional): One or more layers "Fields Glass"
Type G1 or G2 product or "Fields M66 RubrGlas2".
Polyester (Can be reversed with Base Sheet or Ply Sheet layer): One or
more layers polyester (min weight 3 oz/sq yd) (Not UL Classified), applied
in hot asphalt "Fields F100 PowrCoat", "Fields F110 PowrLap",
"Fields M700 RubrGard", "Fields F700 PowrGard" or
"Fields F750 PowrGard2", 2.5-3.5 gal/sq.
Coating and Surfacing Options:
Note: The following systems A through D are options only when "Fields
F100 PowrCoat" or "Fields F110 PowrLap" is used to adhere
the base, ply and/or Polyester.
A. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap ", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 , F550 SunShield"or "Fields
F640 SolrShield2, F630 SolrShield3 or F650 SolrShield", 1-2 gal/sq.
B. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap ", 2.5 or more gal/sq.Surfacing: No. 11 roofing granules,
50 or more lbs/sq or aluminum flakes at 3 or more lbs/sq.
C. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap ", 2.5 or more gal/sq.
Surfacing: "Fields M800 RubrStar" or "Fields F880
SunGard", 1-2 gal/sq.
D. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap ", 2.5 or more gal/sq.
Surfacing: "Fields M860 PolrBrite" or "Fields M850
PolrShield", 1-2 gal/sq.
Note: The following systems E through G are options only when "Fields
M700 RubrGard", "Fields F700 PowrGard" or "Fields
F750 PowrGard2" are used to adhere the Polyester.
E. Coating: "Fields M700 PowrGard", 2.5 or more gal/sq.
Surfacing (Optional): "Fields F540 SunShield 2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard", "Fields
M860 PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq.
F. Coating: "Fields F700 PowrGard", "Fields F750
PowrGard2", "Fields M800 RubrStar" or "Fields F880
SunGard", 2.5 or more gal/sq.
G. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 3 or more gal/sq with or without chopped roving glass,
1 lb. or more/sq.
Surfacing (Optional): "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard", "Fields
M860 PolrBrite" or "Fields F880 SunGard", 1-2 gal/sq or
No. 11 roofing granules at 50 or more lbs/sq or aluminum flakes at 3 or
more lbs/sq.
2. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A or B covered with:
Insulation: (Optional) Any thickness, one or more layers UL Classified
perlite, glass fiber, polyisocyanurate, polyisocyanurate/composite or
PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G2 product.
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product.
Coating and Surfacing Options:
A. Flood-Coat (Optional): Hot roofing asphalt covered with one
of the following surfacings:
Surfacing: "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
1-2 gal/sq, "Fields M800 RubrStar", "Fields F880 SunGard",
"Fields M850 PolrShield", 1 or more gal/sq.
B. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield"
or "Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
1/2 gal/sq; "Fields M800 RubrStar", "Fields F880 SunGard",
"Fields M850 PolrShield" or "Fields M850 PolrShield",
1-2 gal/sq.
C. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap, 2.5 or more gal/sq.
Surfacing: No. 11 roofing granules, 50 ore more lb/sq or aluminum
flakes at 3 lbs/sq.
D. Coating: "Fields F700 PowrGard"
or "Fields F750 PowrGard2" or "Fields M800 RubrStar"
or "Fields F880 SunGard", 2.5 or more gal/sq.
E. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 2.5 or more gal/sq.Surfacing: No. 11 roofing granules
at 50 lbs/sq or aluminum flakes at 3 lbs/sq.
F. Coating: "Fields M860 PolrBrite" or "Fields M850
PolrShield", 2-3 gal/sq.
G. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 2.5 or more gal/sq with or without chopped roving glass,
1 or more lb/sq.
Surfacing (Optional): "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard", "Fields
M860 PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq.
3. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A or B covered with:
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, glass fiber, polyisocyanurate, polyisocyanurate/composite or
PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G2 product,
hot mopped.
Ply Sheet (Optional): One or more layers "Fields Glass"
Type G1 or G2 product, hot mopped.
Polyester: One or more layers "Fields Polyester" (max
weight 5.4 oz/sq yd) (Not UL Classified) applied in hot roofing asphalt,
25 lbs/sq.
A. Flood-Coat: Hot roofing asphalt covered with one of the following
surfacings:
Surfacing: "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields F700 PowrGard", "Fields F750 PowrGard2", "Fields
M800 RubrStar", "Fields F880 SunGard", "Fields M860
PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq or "Fields
F700 PowrGard" or "Fields F750 PowrGard2", 2.5 or more
gal/sq with optional surfacing of No. 11 roofing granules, 50 or more
lb/sq or aluminum flakes at 3 or more lbs/sq.
B. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: No. 11 roofing granules, 50 or more lb/sq or aluminum
flakes at 3 lbs/sq.
4. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A, B or C, gravel or smooth surfaced,
covered with:
Insulation (Optional): Any thickness, one or more layers Johns
Manville "Retro-Fit" cover board, "Fesco", "Fesco-Foam",
"ISO 1", "ENRGY-2", 3/4 in. "Fesco" over
polystyrene or any UL Classified polyisocyanurate insulation, mechanically
fastened or hot mopped.
Ply Sheet: One or more plies Type G1 or G2, nailed or hot mopped.
Membrane: "Fields M68" (modified bitumen), hot mopped.
5. Deck: C-15/32 Incline: 1/2
Existing Roof System: Class A or B granule or smooth surfaced,
covered with:
Base Coat: "Fields M850 PolrShield " or "Fields
M860 PolrBrite" 2-3 gal/sq.
Polyester (Optional): One or more layers polyester (max weight
5.4 oz/sq yd).
Surfacing: "Fields M850 PolrShield" or "Fields M860
PolrBrite", 2-3 gal/sq.
------------------------------------------------------------------------
|