UL CLASSIFICATIONS
COLD APPLICATION SYSTEMS
Unless otherwise indicated, the base sheet may be mechanically
secured, spot or fully adhered along with the ply, cap and/or polyester
sheets with "Fields F100 PowrCoat" or "Fields F110 PowrLap"
at the rate of 2.5 or more gal/sq.
When a Type G3 "F58 GlasCap" is applied with the mineral side
down as an alternate to any specified base sheet directly over a combustible
deck, omit the use of "Kraft Sheathing Paper".
"Fields M100 RubrCoat Fibered Roof Coating" may be substituted
for "Fields F100 PowrCoat" in all applicable Classifications,
which do not exceed 1/2 in. incline.
"Fields M150 RubrSeal" may be substituted for "Fields F110
PowrLap" in all applicable Classifications, which do not exceed 1/2
in incline.
"Fields F600 FlameBloc" or " M600 FireBloc" may be
substitued for "Fields 500 or 600 series Aluminum Coating" in
all Classifications.
"Fields M700 RubrGard" may be substituted for "Fields F700
PowrGard" in all applicable Classifications.
Two Type G1 products may be substituted for one Type G2 product in any
of the following Classifications.
Type G3 "F58 GlasCap" may be substituted as a surfacing option
in all applicable Classifications.
Gravel or slag may be substituted as a surfacing option in all applicable
Classifications.
"Fields T3 Type 3", "Fields T4 Type 4 (hot asphalt)",
"Fields MT3 RubrPac"or "Fields MT4 RubrPac" (SEBS
modified hot asphalt) may be substituted for "Fields F100 PowrCoat",
"Fields M100 RubrCoat Fibered Roof Coating", "Fields F110
PowrLap", "Fields M150 RubrSeal" in all applicable Classifications,
which do not exceed 1/2 in. incline.
"Fields M62 RubrGlas", "Fields M66 RubrGlas" may be
substituted for "Fields Glass" Type G1 and G2 products in all
Classifications.
Class A
1. Deck: NC Incline: 1/2
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite
or PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G1 or
G2 product.
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product.
Coating and Surfacing Options:
A. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield",
"Fields F640, SolrShield2, F630 SolrShield 3 or F650 SolrShield ",
"Fields F700 PowrGard" or "Fields F750 RainGard",
"Fields M800 RubrStar", "Fields M860 PolrBrite""Fields
F880 SunGard or " Fields M850 PolrShield", 1-2 gal/sq.
B. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 2.5 or more gal/sq with or without chopped roving glass,
1 or more lb/sq.
Surfacing (Optional): "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard""Fields
M860 PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq.
2. Deck: NC Incline: 3/4
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite
or PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G1 or
G2 product.
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product.
Coating and Surfacing Options:
A. Coating: "Fields F700 PowrGard" or "Fields F750
PorGard", 2.5 or more gal/sq; "Fields F880 SunGard" 1-2
gal/sq.Surfacing: "Fields M800 RubrStar", 1 gal/sq; "Fields
F880 SunGard", 1-2 gal/sq.
B. Coating: "Fields M800 RubrStar", 2.5 or more gal/sq;
"Fields F880 SunGard", 1-2 gal/sq.
C. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard", 2.5 or more gal/sq.
Surfacing: No. 11 roofing granules at 50 lbs/sq.
3. Deck: NC Incline: 3/4
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite
or PAROC roof insulation.
Base Sheet (Optional): Any "Fields Glass" Type G2 product.
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product.
Cap: "F58 GlasCap" Type G3.
4. Deleted.
5. Deck: C-15/32 Incline: 1
Insulation: Any thickness, one or more layers Johns Manville "Fesco"
or any UL Classified polyisocyanurate insulation. One layer of 1/2 in.
"Retro-Fit" cover board may be placed on top of the above insulations
but is not acceptable by itself.
Base Sheet: Type G2 "Fields Glass".
Ply Sheet: Type G1 "Fields Glass".
Cap Sheet: Type G3 "F58 GlasCap".
6. Deck: NC Incline: 1/2
Insulation (Optional): Any thickness, one or more layers UL Classified
perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite
or PAROC roof insulation.
Base Sheet (Optional) (May be interchanged with ply sheet layer)
: One layer polyester "Fields F50 PolyShield", "Fields
F55 PolyShield2", "Fields M60 RubrPoly" or "Fields
M64 RubrPoly2" or more layers polyester (min weight 3 oz/sq yd) (Not
UL Classified).
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product or "Fields M66 RubrGlas2".
Coating and Surfacing Options:
A. Coating: "Fields F100 PowrCoat", "Fields M100
RubrCoat", "Fields F110 PowrLap", "Fields M150 RubrSeal",
2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
1-2/ gal/sq, "Fields M800 RubrStar", "Fields F880 SunGard",
"Fields M860 PolrBrite" or "Fields M850 PolrShield",
1 or more gal/sq.
B. Coating: "Fields F100 PowrCoat", "Fields M100
RubrCoat""Fields F110 PowrLap" or "Fields M150 RubrSeal",
2.5 or more gal/sq.
Surfacing: Aluminum flakes at 3 lbs/sq or No. 11 granules at 50
lbs/sq.
C. Coating: "Fields F700 PowrGard", "Fields M700
RubrGard" or "Fields F750 PowrGard", 2.5 or more gal/sq.
Surfacing: Aluminum Flakes at 3 or more lbs/sq.
Class B
1. Deck: C-15/32 Incline: 1/2
Insulation (Optional): Any thickness, one or more layers UL Classified
glass fiber, polyisocyanurate/composite or PAROC roof insulation, perlite
(3/4 in. min thickness), polyisocyanurate (2 in. min thickness).
Bottom Layer: "Kraft Sheathing Paper", mechanically secured.
(May be omitted when roof insulation is used).
Base Sheet: Any "Fields Glass" Type G2 product.
Ply Sheet: Two or more layers "Fields Glass" Type G2
product or one "Fields Glass" Type G2 followed by one or more
layers of "Fields Glass" Type G1 product.
Coating and Surfacing Options:
A. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield ",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield ",
1-2 gal/sq; "Fields M800 RubrStar", "Fields F880 SunGard",
"Fields M860 PolrBrite" or "Fields M850 PolrShield",
1-2 gal.
B. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: No. 11 roofing granules, 50 or more lbs/sq. aluminum
flakes at 3 or more lbs/sq.
C. Coating: "Fields F700 PowrGard", "Fields F750
PowrGard", "Fields M800 RubrStar" or "Fields F880
SunGard", 2.5 or more gal/sq.
D. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 2.5 or more gal/sq.
Surfacing (Optional): No. 11 roofing granules at 50 or more lbs/sq
aluminum flakes at 3 lbs/sq.
E. Coating: "Fields M860 PolrBrite" or "Fields M850
PolrShield", 2-3 gal/sq.
F. Coating: "Fields F700 PowrGard" or "Fields F750
PowrGard2", 2.5 or more gal/sq with or without chopped roving glass,
1 or more lb/sq.
Surfacing (Optional): "Fields F540 SunShield2 or F550 SunShield",
"Fields F640 SolrShield2, F630 SolrShield3 or F650 SolrShield",
"Fields M800 RubrStar", "Fields F880 SunGard", "Fields
M860 PolrBrite" or "Fields M850 PolrShield", 1-2 gal/sq.
2. Deck: C-15/32 Incline: 1/2
Insulation (Optional): Any thickness, one or more layers UL Classified
glass fiber, polyisocyanurate/composite or PAROC roof insulation, perlite
(3/4 in. min thickness), polyisocyanurate (2 in. min thickness).
Bottom Layer: "Kraft Sheathing Paper", mechanically secured.
(May be omitted when roof insulation is used).
Base Sheet: Any "Fields Glass" Type G2 product.
Ply Sheet: One or more layers "Fields Glass" Type G2
product or one "Fields Glass" Type G2 followed by one or more
layers of "Fields Glass" Type G1 product.
Polyester (Can be reversed with Base Sheet or Ply Sheet layer): One layer
polyester "Fields F50 PolyShield", "Fields F55 PolyShield2",
"Fields M60 RubrPoly", "M64 RubrPoly2" or one or more
layers polyester (min weight 3 oz/sq yd) (Not UL Classified).
Coating and Surfacing Options:
A. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: "Fields F540 SunShield2 or F550 SunShield"
or "Fields F640 SolrShield2, F630 SolrSheild3 or F650 SolrShield",
1-2 gal/sq; "Fields F880 SunGard", "Fields M860 PolrBrite",
"Fields M850 PolrShield", 1-2 gal or "Fields F700 PowrGard"
or "Fields F750 PowrGard2", 2.5 or more gal/sq. with optional
surfacing of No. 11 roofing granules, 50 or more lb/sq. or Aluminum Flakes
at 3 or more lbs/sq.
B. Coating: "Fields F100 PowrCoat" or "Fields F110
PowrLap", 2.5 or more gal/sq.
Surfacing: No. 11 roofing granules, 50 or more lb/sq or aluminum
flakes at 3 lbs/sq.
3. Deck: C-15/32 Incline: 3/4
Insulation (Optional): Any thickness, one or more layers UL Classified
glass fiber, polyisocyanurate/composite or PAROC roof insulation, perlite
(3/4 in. min thickness), polyisocyanurate (2 in. min thickness).
Base Sheet (Optional): Any "Fields Glass" Type G2 product.
Ply Sheet: One or more layers "Fields Glass" Type G1
or G2 product.
Cap: "F58 GlasCap" Type G3.
4. Deleted.
5. Deck: NC Incline: 3
Insulation (Optional): Any thickness, one or more layers Johns
Manville "Fesco" or any UL Classified polyisocyanurate insulation,
fully adhered in combination (optional) with 1/2 in. "Retro-Fit"
cover board or 3/4 in. "Fesco" over polystyrene.
Base Sheet: Type G2 "Fields Glass".
Ply Sheet: One or more plies Type G1 "Fields Glass".
Cap Sheet: Type G3 "F58 GlasCap".
6. Deck: NC Incline: 3
Insulation (Optional): Any thickness, one or more layers Johns
Manville "Fesco", "Fesco-Foam", "Fes-Core"
or any UL Classified polyisocyanurate insulation, fastened in combination
(optional) with 1/2 in. "Retro-Fit" cover board or 3/4 in. "Fesco"
over polystyrene.
Ply Sheet: Two or more plies Type G1 "Fields Glass".
Cap Sheet: Type G3 "F58 GlasCap".
7. Deck: C-15/32 Incline: 1/2
Vapor Barrier: Kraft paper nailed.
Base Sheet: One layer of (5.4 oz/square yd) polyester fabric (not
Classified) adhered with "Fields M100 RubrCoat" at 3.0 gal/sq.
Ply Sheet: Two plies of "Fields M66 RubrGlas 2" (SEBS
Base Sheet) or Type G2 adhered with "Fields M100 RubrCoat" at
3.0 gal/sq.
Surfacing: "Fields M100 RubrCoat" at 2.5 gal/sq. with
either 50 lb/sq. of roofing granules or 3 lb/sq. of aluminum flakes spread
into the coating.
|